New Interconnect Technology for Modern Soldier Systems

MIGHTY MOUSE Low-Profile Cobra Plug Connectors

805-061 triple-start with self-locking coupling nut, exploded view

How To Order Mighty Mouse Cobra Plug Connector and Backshell Assemblies

B Thread

Master Key

Sample Part Number

801-069-26

ZNU 8-13 P A 1 05

801-069-26 Double-Start self-locking plug with ratchet mechanism (the clicker) 804-066-06 QDC Push-Pull plug 805-061-16 Triple-Start plug with ratcheting anti-decoupling mechanism

Connector Series and Mighty Mouse Cobra Basic Part Number

M = Aluminum / Electroless Nickel RoHS Compliant NF = Aluminum / Cadmium with Olive Drab Chromate ZNU = Aluminum / Zinc-Nickel with Black Chromate MT = Aluminum / Nickel-PTFE RoHS Compliant Z1 = Stainless Steel / Passivated RoHS Compliant

F

Material/Finish

Shell Size - Contact Arrangement

See Table V - A: 801-069 B: 804-066 C: 805-061

A = Pin, Solder B = Socket, Solder P = Pin, Crimp S = Socket, Crimp

Contact Style

ØC J

Polarization Key Position

A , B , C , D , E , F - See Table II

Cable Exit Direction

1 , 2 , 3 , 4 , 5 , 6 , 7 , 8 - See Table I

Cable Entry Size

See Table VI

Table VI - Cable Entry

Table II: Key Positions

Table I: Cable Exit Direction

Code

Entry Size

Code

Entry Size

Cable Exit Direction Code

A°

B°

C°

02 03 04 05 06 07 08 09

.125 .188 .250 .313 .375 .438 .500 .563

10 11 12

.625 .688 .750 .813 .875 .938 1.000 1.063

C°

A B C D

150° 210° 75° 210° 95° 230° 140° 275° 75° 275° 95° 210°

Master Key

1 2 3 4 5 6 7 8

0°

13* 14* 15* 16* 17*

45° 90°

B° A°

135° 180° 225° 270° 315°

E F

* Entry codes 13-17 not available for Series 804 Cobra

Cable Exit Direction (Direction 2 Shown)

Table V - Shell Size/Contact Arrangements

A: 801-069

B: 804-066

C: 805-061

Shell Size

Max Entry

Shell Size

Max Entry

Shell Size

Max Entry

Contact Arr.

Contact Arr.

Contact Arr.

MATERIALS/FINISH • Contacts: Copper alloy, gold plated • Backshell Housing, Connector Shell, Coupling Nut and Lid: Aluminum or Stainless Steel • Backshell Sealing Gasket and Interfacial Seal: Fluorosilicone • Screws: 300 Series Stainless Steel • Insulator: LCP NOTES • Rear insulator grommet not supplied. • Cobra plugs mate with respective series receptacles with same layout, polarization and opposite contact gender.

5 6

5-3

03 04 05 06 07 08 09

5 6

5-3

03 04 05 06 07 08

8 9

8-4, 8-6, 8-7

04 05 06 07 08 09

6-4, 6-6, 6-7

6-4, 6-6, 6-7

9-10 10-13 11-19 12-26 13-31 15-37 18-55 19-85 21-100 23-130

7

7-10 8-13 9-19

7

7-10 8-13 9-19

10 11 12 13 15 18 19 21 23

8 9

8 9

10 11 13 16 17 19 21

10-26 11-31 13-37 16-55 17-85 19-100 21-130

10 12 14

10-26 12-37 14-55

10 12

10 12 13 15 17

10 12 13 15 17

• Hand crimp tool: P/N 809-015. Positioner for hand tool: P/N 809-005. Insertion/extraction tool P/N 809-088.

• Crimp barrel accommodates 22, 24, 26 and 28 gage wire. • All Cobra plugs equipped with Size #23 contacts.

27 © 2015 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324

Powered by