STAR-PAN™ Mission Manager

JTAC-TOUGH ™ STAR-PAN ™ VI 808-037 6 port smart power and data hub system

OVERVIEW The Glenair STAR-PAN™ VI Hub is a lightweight, durable, compact data and power distribution hub, ruggedized for harsh environment dismounted soldier applications. The connectorized hub provides a data backplane with power monitoring and management to connected external peripherals used in Digitally Aided Close Air Support (DACAS) and other mission applications. The hub is compatible with USB1.1, USB2.0 (full and high speed), and SMBus protocols. STAR-PAN™ VI contains two power inputs for extended missions. Two radio ports capable of powering up the USB Data backplane and host connection. A dedicated charge port for use with smart batteries and auxiliary power sources including multiple DC power sources such as vehicle power, solar panels, kinetic energy devices or fuel cells. All connector interfaces are compliant to the NATO STANAG 4695 standard for Soldier Power Connectors PAN APPLICATIONS „ JTAC Digitally Aided Close Air Support (DACAS) „ Tactical ops center operations commander „ Search and rescue commander

HOW TO ORDER Sample Part Number:

808-037

Connectorized Hub

STAR-PAN VI 6-port power/data hub

PERFORMANCE SPECIFICATIONS Operating Conditions Storage Temperature STAR-PAN VI PORT CONFIGURATION EUD 1 RADIO 2 PAN 4 POWER 2

-40°C to +80°C -32°C to +49°C

Operating Temperature

Operation Altitude Storage Altitude

9754m 15240m

Water Immersion, Mated

MIL-STD-810, Method 512, 1m for 1 hr.; IP67 rated dust / water resistant

Host & Pan 1–4 Battery Voltage

10.0V to 20.0V, 14.8V typical

Battery Supply Current

5A Maximum per individual port

+5V Backup Total Supply Current

5A based on radio supply, Radio 1 primary

USB +/USB -

-0.5V to +3.5V

Radio 1 and 2 Ports Battery Voltage Battery Supply Current

10.0V to 20.0V, 14.8V typical. Highest priority for power management

5A maximum per individual port

+5V Back Up Supply Current +5V Back Up Supply Current

1.2A typical, 3A max, based on radio supply, radio 1 primary

.5A per port -0.5V to +3.5V

USB +/USB -

Auxiliary Power Supply Port Auxiliary Voltage Source Auxiliary Supply Current

10V to 36V

5 A maximum system supply current

Battery Port Battery Input Voltage Battery Supply Current Battery Charge Current

10V to 20V

5A maximum system supply current

3A

(4.20)

(.64)

(.64)

(4.20)

(4.50)

(4.50)

33 © 2020 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324 • STAR-PAN ™ Tactical Interconnect Solutions [QC] Dimensions are subject to change without notice.