SERIES 96 TurboFlex ultra-flexible power distribution cable Environmental performance · voltage rating data Duralectric ™ jacketing specifications and colors
TURBOFLEX CABLE APPLICATION EXAMPLE
This multibranch TurboFlex power and data interconnect assembly for a ruggedized defense application demonstrates the remarkable flexibility and minimal bend radius of large form-factor (up to 450 MCM) TurboFlex cable. Example shown features UV- and chemical-resistant Duralectric jacketing in FED-STD 595C Safety Orange.
Voltage Ratings
Jacket Wall Thickness
P/N
AC Voltage Rating, RMS
DC Voltage Rating
961-004 961-003 961-002 961-001
.032" .062" .093" .125"
2000 3000 3500 4500
2800 4200 4900 6300
Ultra flexible rope lay construction TurboFlex bend radius is 3X the outer diameter
Standard catalog product is available with either Tin/Copper, Silver/Copper, or Nickel/ Copper conductors, with standard Duralectric™ jacketing in four wall thicknesses. Consult factory for special formula Duralectric™ K, F, and C configurations
Jacketing Options Weatherproof, halogen free, flame resistant, functional to 260°C
TURBOFLEX® WITH DURALECTRIC™ JACKETING: ENVIRONMENTAL PERFORMANCE Temperature rating: -60°c to 260°c Halogen free per IEC 60614-1
Low smoke toxicity per NES 713, tested value of 1.9 Fungus rating of 0 per MIL-STD-810g method 508.5, Does not support fungal growth ASTM D624, die B tear strength, 150 pounds per inch minimum on jacket material Low outgassing per ASTM e595 after post curing, TML .06%, CVCM .006%, WVR .02% Resistant to fluids per MIL-STD-810F, method 504 JP-8 per MIL-DTL-83133 (NATO type 34) MIL-H-5606 hydraulic fluid MIL-PRF-23699 lubricating oil MIL-C-85570 cleaner TT-I-735 Isopropyl alcohol AMS 1432 potassium acetate deicing/anti- icing fluid MIL-C-87252 coolant Amerex AFF fire extinguishing foam
0 Black Fed-Std-595C #17038 1 Desert Tan Fed-Std-595C #33446 2 Red Fed-Std-595C #11120 3 Orange Fed-Std-595C #12300 4 Yellow Fed-Std-595C #13591 5 Green Fed-Std-595C #14193 6 Blue Fed-Std-595C #15125 7 Violet Fed-Std-595C #17142 8 Gray Fed-Std-595C #26270 9 White Fed-Std-595C #17875 Consult factory for other specific Fed Std colors
Accelerated weathering and simulated solar radiation at ground level per IEC 60068-2-5; 56 Days exposure, suitable for greater than 50 years of service in direct sunlight Flame resistant per IEC 60614-1 Flame resistant per UL 1685, section 12 (FT4/ IEEE120), vertical-tray fire-propagation and smoke release test Flame resistant per FAR 25.853 (A) amendment 25-116, appendix Fpart I (A) (1) (i), 60 second vertical burn test Limiting oxygen index of 45 per ISO 4589-2:1999 Low smoke per NES 711, smoke density of 11.75 Smoke density class F1 per NF F 16-101 IAW DIN EN 60695-2-11:2011
Abrasion Resistance Wear Resistance Flame Resistance Sunlight Resistance
Good Good
Excellent Excellent Excellent
Flex Resistance
31 © 2021 Glenair, Inc • 1211 Air Way, Glendale, CA 91201 • 818-247-6000 • www.glenair.com • U.S. CAGE code 06324 • eVTOL Air Taxi Interconnect Solutions